Skip to product information
1 of 8

Tripp Lite by Eaton

Tripp Lite Pdumv20Hvnetlx 3.7Kw Single-Phase Switched Pdu - Lx Interface, 208/230V Outlets (20 C13 & 4 C19), C20/L6-20P, 0U, Taa

Tripp Lite Pdumv20Hvnetlx 3.7Kw Single-Phase Switched Pdu - Lx Interface, 208/230V Outlets (20 C13 & 4 C19), C20/L6-20P, 0U, Taa

SKU:PDUMV20HVNETLX

Regular price $766.93
Regular price Sale price $766.93
Sale Sold out
Shipping calculated at checkout.
          View full details
          Description
          Specifications
          Reviews, Que. & Ans.

          Description :

          3.7kW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (20 C13 & 4 C19), C20/L6-20P, 0U, TAA

          Tripp Lite PDUMV20HVNETLX 3.7kW Single-Phase Switched PDU - LX Interface, 208/230V Outlets (20 C13 & 4 C19), C20/L6-20P, 0U, TAA. PDU types: Switched, Rack capacity: 0U, Type: Single-phase. AC outlets quantity: 24 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: C20 coupler. LED indicators: Power, Status, Cable length: 3.05 m, Certification: TAA, UL, CE, FCC, NOM, EN55022:2010+2011, EN55024:2010. Supported network protocols: HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, NTP. Nominal input voltage: 200-240 V, Maximum current: 20 A

          The PDUMV20HVNETLX 3.3-3.7kW Single-Phase Switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. Recommended for any IT or industrial application, it features 24 switched outlets (20 C13 and 4 C19) with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A 10-ft. (3.05 m) cord with NEMA L6-20P plug connects the PDU's C20 inlet to a compatible AC power source, generator or protected UPS.

          The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

          A digital ammeter allows you to monitor each bank's load in real time to ensure it remains well below maximum capacity with no danger of overload. The vertical PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

          Distributes Network-Grade Single-Phase Power
          3.3-3.7kW 208/230V switched PDU
          Recommended for network applications requiring individual outlet control, load shedding and remote monitoring of critical network components
          Includes detachable NEMA L6-20P plug with 10-ft. (3.05 m) cord; C20 inlet supports user-supplied international input cabling
          Firmware upgrades support future product enhancements

          24 Switched Outlets Distribute AC Power
          20 C13 and 4 C19 outlets split into 2 separately breakered load banks
          Individual outlets can be remotely controlled to power up, power down, reboot or lock out devices
          Plug-lock inserts prevent cables from becoming accidentally disconnected

          Digital Ammeter
          Reports load level on each bank and total PDU output
          Supports IP-address self-ID
          Rotates 180° for easy reading at either angle

          Built-In LX Platform Interface
          Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
          PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
          IP-based Auto Probe detects lost connectivity and restores service autonomously

          Easy 0U Installation in EIA-Standard 19 in. Racks
          Mounts vertically using included toolless buttons or rack-mounting brackets
          Included PDUMVROTATEBRKT allows mounting with rear-facing outlets

          TAA-Compliant
          Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

          Specifications :

          General Information

          Manufacturer Tripp Lite by Eaton
          Manufacturer Part Number PDUMV20HVNETLX
          Manufacturer Website Address https://tripplite.eaton.com/
          Brand Name Tripp Lite by Eaton
          Product Model PDUMV20HVNETLX
          Product Name PDUMV20HVNETLX 24-Outlet PDU
          Product Type PDU
          UPC 037332205292
          Height70"
          Width2.2"
          Depth2.7"
          Weight (Approximate)8.50 lb

          Miscellaneous

          Package Contents
          • PDUMV20HVNETLX 24-Outlet PDU
          • Built-in LX Platform Interface
          • Detachable NEMA L6-20P to C19 power cord, 10 ft.
          • Configuration Cable
          • 24 x Plug-lock Inserts
          • Rack-mounting Hardware
          • Mounting Bracket Accessory
          • Owner's Manual
          Environmentally FriendlyYes

          Warranty

          Limited Warranty2 Year

          Customer Reviews

          Reviews 0
          Questions 0
          Ask your Question about this product